
- Chinese Optics Letters
- Vol. 21, Issue 10, 101201 (2023)
Abstract
1. Introduction
Since the beginning of the 21st century, with the rapid development of microelectronics manufacturing, ultraprecision machining, aerospace, and other fields, high-precision and high-sensitivity microdisplacement measurements have received significant attention[1–3]. Currently, these measurement techniques are roughly divided into two categories: nonoptical and optical methods. Nonoptical methods include capacitive and inductive sensors[4–6]. Although these methods can achieve high-resolution, high-precision, and low-power microdisplacement measurements, their measurement range is only from tens of nanometers to micrometers[7]. In contrast, optical methods, including grating interferometry and laser interferometry[8–11], are widely used in microdisplacement measurements owing to their laser monochromaticity and good coherence[12,13]. The most advanced lithography machine, produced by advanced semiconductor material lithography (ASML), uses two-dimensional grating measurement technology. The grating displacement measurement is based on the grating pitch, which has low sensitivity to the external environment, and the repeated positioning accuracy can reach several nanometers[14]. However, in the grating production process, an ultraprecise laser interferometer is still required for positioning and motion locking[15]. Therefore, in modern ultraprecision processing, laser interferometry is widely used, owing to its advantages of traceability, high measurement accuracy, fast response time, and being noncontact.
The Michelson interferometer is the most typical laser interferometer. The measurement beam is reflected by the target and interferes with the reference beam, and the intensity of the interference signal varies periodically according to
Chu et al.[16] proposed a signal subdivision method that can be used in laser interferometers. The combination of a double threshold method and tangent subdivision method overcomes the inconsistency in the sensitivity of the ratio-amplitude subdivision method within a signal period. However, the signal-to-noise ratio of the fringe signal directly determines the signal subdivision accuracy, thus limiting system performance. Xu et al.[17] designed a nanopositioning system using a polarization laser interferometer. The photoelectric sensor of the traditional single-frequency laser interferometer is replaced by a polarimeter and equipped with polarization beam-splitting elements, polarizers, etc. The displacement is converted into the rotation angle of the synthesized light in the vibration direction using the interference optical path, and the discrimination of the displacement direction is realized. The minimum step size of the system reaches 5 nm. When building the single-frequency polarization laser interferometer, the polarizer requires strict adjustment at 45° in both directions; otherwise, phase errors will be introduced[18], and the intensity noise generated by the laser spontaneous radiation will also affect the interferometric system[19]. The use of phase compensation and orthogonal detection technology can effectively reduce the impact of nonideal system construction and laser intensity noise[20–22] and improve the measurement accuracy and stability of laser interferometers. Cui et al.[23] studied a novel single-frequency laser interferometer for nanometer measurement and constructed a four-way quadrature detection structure. They also eliminated the polarization mixing cross talk with the minimum number of quadrature phase error sources and reduced the interferometer period nonlinearity error to 0.2 nm by offset correction. However, the arctangent algorithm in the phase resolution process is restricted by the pole limitation. Therefore, the signal amplitude carrying phase information needs to be quantized, sampled, and electronically subdivided to obtain the phase change, and the electronic subdivision accuracy limits the system resolution.
Sign up for Chinese Optics Letters TOC. Get the latest issue of Chinese Optics Letters delivered right to you!Sign up now
In this study, taking advantage of orthogonal detection, an orthogonal dual Michelson interferometer displacement measurement system is built, wherein two mutually orthogonal output signals are used to distinguish the displacement direction. This solves the shortcomings of the uneven ranging sensitivity of the traditional Michelson interferometer. The arc cosine algorithm is used for signal demodulation, which overcomes the problem of poles in the arctangent algorithm.
2. Experimental Setup and Principle Analysis
A schematic of the orthogonal double Michelson interferometer is shown in Fig. 1. A semiconductor laser (with a line width of 100 kHz and power stability within
Figure 1.Experimental setup for the orthogonal dual interferometer.
The calibration mirror is fixed on the nanopositioning stage together with the target mirror. The picometer precision laser interferometer (Attocube Systems AG brand IDS3010, with strong ranging capability[24,25]) is used to calibrate the distance measurement results of the dual-interferometer system.
For the light coming out of the emitting collimator, the light field can be expressed as
By adjusting the position of reference mirror 2 so that the difference between
Assuming that the target mirror is at a certain position A, Eqs. (6) and (7) are substituted into Eqs. (4) and (5), respectively, and the interference light intensities
Comparing Eqs. (10) and (11), it can be seen that when the target mirror is at a certain position, the interferometric light intensity output from the two detectors varies orthogonally.
Similarly, when the target mirror is moved
A schematic representation of the orthogonal detection method is shown in Fig. 2. When the target reflector is displaced, the output current is corrected for DC offset, and the amplitude is normalized to obtain blue and red lines that vary orthogonally, as shown in Fig. 2(a).
Figure 2.(a) Two quadrature signals generated; (b) Lissajous graph.
Using Eqs. (10) and (11), the phase
Similarly, the phase
Assuming that all the noise introduced by the system is transformed into intensity noise with a coefficient of
Evidently, by substituting Eqs. (17) and (18) into Eqs. (14), the phase can still be demodulated. The effect of the noise on the interferometric system can be effectively eliminated using the orthogonal detection and inverse cosine demodulation algorithms.
The direction of the displacement can also be determined by measuring the two interferometric signals while measuring the displacement. In Fig. 2(b), the normalized interferometric signals
3. Experimental Results
3.1. Displacement direction discrimination
When the target mirror performs a sinusoidal vibration with a peak-to-peak value of 20 µm and a frequency of 5 Hz, the two interference signals received by PD1 and PD2 are processed to obtain the mutually orthogonal sine/cosine curves, as shown in Figs. 3(a) and 3(b), respectively. When the target mirror moves along the
Figure 3.(a) Interference signal received by PD1; (b) interference signal received by PD2; (c) interference signal variation diagram when the displacement direction is changed; (d) Lissajous figure when moving along the x direction; (e) Lissajous figure when moving along the −x direction.
3.2. Nanometer-scale displacement measurement results
For comparison with the ranging results of the traditional interferometer, only the NPBS1, reference mirror 1, target mirror, and receiving collimator 1 were used to form the traditional interferometer. The target mirror moved 20 nm every 200 ms for 18 times. The traditional interferometer only provides an output interference signal
Figure 4.(a) Conventional interferometer single-channel data acquisition; (b) phase difference resulting from each displacement; (c) orthogonal dual-interferometer two-way data acquisition; (d) 20 nm step displacement measurement results; (e) 10 nm step displacement measurement results; (f) 5 nm step displacement measurement results.
Consistent with the ranging conditions of a conventional interferometer, the orthogonal double interferometer adds an output signal. When the target moves, two mutually orthogonal interferometric signals are output by PD1 and PD2, as indicated by the red and blue lines in Fig. 4(c). The data were averaged every 200 ms to obtain the yellow line shown in Fig. 4(c). The phase change
Substituting the phase change produced by each displacement into Eq. (16), the measured displacement of the dual-interferometer system is plotted, as indicated by the yellow points in Fig. 4(d). The measured displacement of the calibration interferometer is shown as the blue points in Fig. 4(d). Considering the measurement results of the calibration interferometer as a benchmark, the displacement error of the dual-interferometer system is plotted, as indicated by the red dots in Fig. 4(d). The experimental results show that, in the case of a displacement step of 20 nm, the dual-interferometer system using orthogonal detection has a high consistency with the measurement results of the calibration interferometer. The single measurement error fluctuates within
Figures 4(e) and 4(f) show two sets of measurement results for the orthogonal dual interferometer and the calibration interferometer with displacement steps of 10 and 5 nm, respectively. The blue points represent the measurement values of the calibration interferometer, the yellow points represent the measured displacement values of the orthogonal double interferometer system, and the displacement error curve is drawn as indicated by the red point. The displacement recovered using the orthogonal dual-interferometer system has a good linear relationship with the displacement measured by the calibration interferometer, and the errors of multiple measurements are basically within
Table 1 lists the displacement measurement results for steps of 20, 10, and 5 nm. The average error increases with the increase of the displacement step. As shown in Fig. 5(a), owing to the installation error of the orthogonal dual interferometer and the calibration interferometer systems, it is shown that there is an angle
Figure 5.(a) Schematic diagram of cosine error; (b) two interference signals when the target is stationary.
Step/nm | Number | Average Error/nm |
---|---|---|
20 | 36 | 0.29 |
10 | 36 | 0.27 |
5 | 36 | 0.12 |
Table 1. Orthogonal Dual-Interferometer Limit Resolution Error Results
The system resolution is limited due to environmental fluctuations as well as system noise and other factors. Under the same experimental conditions, the two interferometric signals were acquired when the target reflector was stationary, as shown in Fig. 5(b). The phase fluctuation when the target is stationary can be demodulated using Eqs. (14) and (15), and the root mean square error of the phase at this time is calculated to obtain the fluctuation of the displacement, which is the system resolution. After acquisition and calculation, the range resolution of the dual-interferometer system was obtained as 700 pm.
The experimental results show that the developed double interferometer system has good repeatability for the measurement of nanoscale fine displacements and can be reliably used in the field of nanoscale displacement measurement.
4. Conclusion
A dual-interferometer high-precision microdisplacement measurement system using orthogonal demodulation was designed to solve the problems of uneven ranging sensitivity and the inability of the traditional interferometer to determine the displacement direction. The inverse cosine algorithm was used for displacement analysis. In the experiment, the minimum step length of the displacement system was measured as 5 nm. The experimental results exhibited a good linear relationship with the measurement results of the calibrated interferometer. The average error is 0.12 nm, and the repeatability is good. The experimental results show that the developed orthogonal double interferometer can realize a microdisplacement measurement of 5 nm with good repeatability, a simple system structure, and practical value.
References
[6] S. Marick, S. C. Bera. Study of a modified differential inductance type displacement transducer. International Conference on Electronics(2014).
[7] Y. Wu, T. Huang. Design of high precision capacitance displacement sensor. IEEE Advanced Information Technology, Electronic and Automation Control Conference(2018).

Set citation alerts for the article
Please enter your email address