• Laser & Optoelectronics Progress
  • Vol. 59, Issue 23, 2306001 (2022)
Wanxu Zhu1,2,*, Wei Wei1,2, Long Yang3, and Mengguo Li1,2
Author Affiliations
  • 1College of Civil and Architectural Engineering, Guilin University of Technology, Guilin 541004, Guangxi, China
  • 2Guangxi Intelligent Structural Materials Engineering Research Center, Guilin 541004, Guangxi, China
  • 3Guangxi Liuzhou Iron and Steel Group, Liuzhou 545000, Guangxi, China
  • show less
    DOI: 10.3788/LOP202259.2306001 Cite this Article Set citation alerts
    Wanxu Zhu, Wei Wei, Long Yang, Mengguo Li. Research on Fatigue Performance of Carbon Fiber Reinforced Polymer Cable Anchor Structure in Water Environment[J]. Laser & Optoelectronics Progress, 2022, 59(23): 2306001 Copy Citation Text show less
    References

    [1] Li Y. Contrastive study of economic performance of long-span suspension bridges with CFRP and steel main cables[J]. World Bridges, 42, 55-60(2014).

    [2] Yu J. The research of the fatigue reliability of bridge cables under corrosive environment[D](2016).

    [3] Benmokrane B, Ali A H, Mohamed H M et al. Laboratory assessment and durability performance of vinyl-ester, polyester, and epoxy glass-FRP bars for concrete structures[J]. Composites Part B: Engineering, 114, 163-174(2017).

    [4] Puigvert F, Gil L, Escrig C et al. Stress relaxation analysis of adhesively bonded anchorages for CFRP tendons[J]. Construction and Building Materials, 66, 313-322(2014).

    [5] Yang W R, He X J, Dai L. Experimental study the durability of CFRP anchor and epoxy resin[J]. Journal of Wuhan University of Technology, 36, 93-96(2014).

    [6] Zhu J L, Yang W R. Experimental investigation on durability of CFRP anchor in acid corrosion environment[J]. New Building Materials, 43, 58-61, 69(2016).

    [7] Zhu Y L, Liu L H, Zhou J Q et al. Research on carbon fiber reinforced polymer stay-cable and its mechanical property[J]. Fiber Reinforced Plastics/Composites, 80-84(2019).

    [8] Hou S W, Qiang S Z, Zhuge P et al. Fatigue test of bond-type anchor for CFRP cables[J]. China Journal of Highway and Transport, 25, 100-106(2012).

    [9] Li S Q, Liu R G, Chen B et al. Static load test and bond stress distribution of improved anchor[J]. Industrial Construction, 46, 157-162(2016).

    [10] Quan Z Q, Fang X Q, Xue G Z et al. Strain transfer coupling mechanism of surface-bonded fiber Bragg grating sensor[J]. Chinese Journal of Lasers, 47, 0104004(2020).

    [11] Sun L, Wang X Y, Li C et al. New double fiber Bragg grating static level based on equal strength beams[J]. Acta Optica Sinica, 41, 1406005(2021).

    [12] Qin H Y, Shen Q X, Zhong Y J. Research on stress monitoring of large-strain carbon fiber plate using fiber Bragg grating sensor[J]. Railway Engineering, 58, 53-56(2018).

    [13] Zhu W X, Shen Q X, Qin H Y. Research and application of FBG monitoring technology in internal prestressed steel strand[J]. Acta Photonica Sinica, 48, 0206002(2019).

    [14] Zhu W X, Yang L, Zhu S C et al. Design and experimental study of multi-cone anchorages for carbon fiber tendons[J]. Industrial Construction, 50, 177-181(2020).

    [15] Demers C E. Tension-tension axial fatigue of E-glass fiber-reinforced polymeric composites: fatigue life diagram[J]. Construction and Building Materials, 12, 303-310(1998).

    Wanxu Zhu, Wei Wei, Long Yang, Mengguo Li. Research on Fatigue Performance of Carbon Fiber Reinforced Polymer Cable Anchor Structure in Water Environment[J]. Laser & Optoelectronics Progress, 2022, 59(23): 2306001
    Download Citation