• Optical Instruments
  • Vol. 44, Issue 3, 14 (2022)
Junzhou CHENG1,2, Mingpeng HU1,*, Yulong WANG1,2, and Wenbo YANG1,2
Author Affiliations
  • 1Institute of Optics and Electronics Chinese Academy of Sciences, Chengdu 610209, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.3969/j.issn.1005-5630.2022.03.003 Cite this Article
    Junzhou CHENG, Mingpeng HU, Yulong WANG, Wenbo YANG. Research on ground simulation testing technology of low orbit TDICCD camera image quality[J]. Optical Instruments, 2022, 44(3): 14 Copy Citation Text show less

    Abstract

    In order to assemble and test a microstructure TDICCD camera, a dynamic MTF test device was proposed and built. The MTF of the camera is measured by the edge method. After theoretical analysis and experimental verification, the measurement accuracy of the device is better than 5%, which meets the design requirements. The device is used to analyze the influence of the two factors of speed-to-height ratio and drift angle on the image quality of TDICCD camera, and the results are consistent with the theory. The construction of this device satisfies the requirements of the ground dynamic MTF test of the TDICCD camera, and has certain engineering significance.
    Junzhou CHENG, Mingpeng HU, Yulong WANG, Wenbo YANG. Research on ground simulation testing technology of low orbit TDICCD camera image quality[J]. Optical Instruments, 2022, 44(3): 14
    Download Citation