• Optics and Precision Engineering
  • Vol. 17, Issue 7, 1630 (2009)
TAN Xiao-yun*, ZHOU Xian-zhong, XU Na, CHEN Wei-ping, and LIU Xiao-wei
Author Affiliations
  • [in Chinese]
  • show less
    DOI: Cite this Article
    TAN Xiao-yun, ZHOU Xian-zhong, XU Na, CHEN Wei-ping, LIU Xiao-wei. Error analysis on numerical double integration in acceleration measurement with clock jitter[J]. Optics and Precision Engineering, 2009, 17(7): 1630 Copy Citation Text show less

    Abstract

    The positioning error of accelerometers due to a clock jitter is analyzed by Monte Carlo analysis method.The simulation results reveal that the distribution of acceleration measurements with the clock jitter is approximately Gaussian distribution,which is well coincident with the theoretical analysis.Moreover,the relation between the variance of integration distance and the clock jitter is analyzed.Both the theoretical and simulation results indicate that the error of numerical double integration due to the clock jitter increases proportional to the clock jitter.When the input acceleration signal is a sine wave with a amplitude of 1g and a period of 1 s,the ratio between the integration error of numerical double integration and the clock jitter is 0.261 1 after 1 s.
    TAN Xiao-yun, ZHOU Xian-zhong, XU Na, CHEN Wei-ping, LIU Xiao-wei. Error analysis on numerical double integration in acceleration measurement with clock jitter[J]. Optics and Precision Engineering, 2009, 17(7): 1630
    Download Citation