• Acta Photonica Sinica
  • Vol. 52, Issue 8, 0812004 (2023)
Yue LI, Yinlin YUAN, Yingjie YE, Deyao KONG..., Lan XIAO, Wenchao ZHAI and Xiaobing ZHENG*|Show fewer author(s)
Author Affiliations
  • School of Environment Science and Optoelectronic,University of Science and Technology of China,Hefei 230026,China
  • show less
    DOI: 10.3788/gzxb20235208.0812004 Cite this Article
    Yue LI, Yinlin YUAN, Yingjie YE, Deyao KONG, Lan XIAO, Wenchao ZHAI, Xiaobing ZHENG. Design and Performance Test of Low Light Level Illumination Source with Wide Dynamic Range[J]. Acta Photonica Sinica, 2023, 52(8): 0812004 Copy Citation Text show less
    Scheme drawing of illuminance source
    Fig. 1. Scheme drawing of illuminance source
    Design drawing of adjustable dynamic range integrating sphere light source unit
    Fig. 2. Design drawing of adjustable dynamic range integrating sphere light source unit
    Mechanical design drawing of adjustable aperture
    Fig. 3. Mechanical design drawing of adjustable aperture
    Schematic diagram of cylinder aperture
    Fig. 4. Schematic diagram of cylinder aperture
    Adjustable aperture adjustment coefficient analysis diagram
    Fig. 5. Adjustable aperture adjustment coefficient analysis diagram
    Adjustable aperture adjustment coefficient T (l)
    Fig. 6. Adjustable aperture adjustment coefficient T l
    Simulation results of output illumination of low light level illuminance source
    Fig. 7. Simulation results of output illumination of low light level illuminance source
    Picture of low light level illuminance source
    Fig. 8. Picture of low light level illuminance source
    Illuminance response coefficient of the monitor detector
    Fig. 9. Illuminance response coefficient of the monitor detector
    Test results of illuminance dynamic range
    Fig. 10. Test results of illuminance dynamic range
    Instability test of wide dynamic range low light illuminance source for 1 h
    Fig. 11. Instability test of wide dynamic range low light illuminance source for 1 h
    ParameterValue
    Reflectivity of inner wall of integrating sphere ρ/%98
    Opening ratio of child integrating sphere f/%4.59
    Opening area of child integrating sphere/mm2176.71
    Opening ratio of parent integrating sphere f/%2.44
    Opening area of parent integrating sphere/mm2314.16
    Adjustment coefficient of adjustable aperture Tl)/%1~1.09×10-6
    Radius of input aperture of cylinder aperture a/mm2
    Radius of output aperture of cylinder aperture b/mm0.5
    Length of cylinder aperture c/mm120
    Table 1. Parameters of wide dynamic range low light level illuminance source
    Yue LI, Yinlin YUAN, Yingjie YE, Deyao KONG, Lan XIAO, Wenchao ZHAI, Xiaobing ZHENG. Design and Performance Test of Low Light Level Illumination Source with Wide Dynamic Range[J]. Acta Photonica Sinica, 2023, 52(8): 0812004
    Download Citation