• Laser & Optoelectronics Progress
  • Vol. 59, Issue 24, 2410009 (2022)
Qing Long, Hongning Li*, Ming Yang**, and Xin Yang***
Author Affiliations
  • School of Physics and Electronic Information, Yunnan Normal University, Kunming 650500, Yunnan , China
  • show less
    DOI: 10.3788/LOP202259.2410009 Cite this Article Set citation alerts
    Qing Long, Hongning Li, Ming Yang, Xin Yang. Improved Three-Dimensional Measurement Method for Structured Light Phase[J]. Laser & Optoelectronics Progress, 2022, 59(24): 2410009 Copy Citation Text show less
    Diagram of experimental principle
    Fig. 1. Diagram of experimental principle
    Diagram of the experimental platform
    Fig. 2. Diagram of the experimental platform
    Result comparison of phase calculation method before and after improvement. (a) Object to be measured; (b) result of traditional phase calculation method; (c) result of improved method
    Fig. 3. Result comparison of phase calculation method before and after improvement. (a) Object to be measured; (b) result of traditional phase calculation method; (c) result of improved method
    Three-dimensional shape restored by improved phase calculation method. (a) Actual image; (b) depth map of phase unwrapping; (c) depth map of phase difference; (d) three-dimensional structured map
    Fig. 4. Three-dimensional shape restored by improved phase calculation method. (a) Actual image; (b) depth map of phase unwrapping; (c) depth map of phase difference; (d) three-dimensional structured map
    Test results for whiteboard. (a) Scene; (b) phase measurement profilometry; (c) time defocus analysis method; (d) proposed method; (e) value in 100th column in Fig. 5 (b); (f) value in 100th column in Fig.5 (c); (g) value in 100th column in Fig.5 (d)
    Fig. 5. Test results for whiteboard. (a) Scene; (b) phase measurement profilometry; (c) time defocus analysis method; (d) proposed method; (e) value in 100th column in Fig. 5 (b); (f) value in 100th column in Fig.5 (c); (g) value in 100th column in Fig.5 (d)
    Experimental results of the proposed method
    Fig. 6. Experimental results of the proposed method
    ParameterTraditional phase calculation methodImproved method
    Error of phase0.14270.1179
    Table 1. Error comparison of phase calculation method before and after improvement
    ParameterPhase measurement profilometryTime defocus analysis methodProposed method
    Error /cm43.3531.0913.20
    Table 2. Error comparison
    Qing Long, Hongning Li, Ming Yang, Xin Yang. Improved Three-Dimensional Measurement Method for Structured Light Phase[J]. Laser & Optoelectronics Progress, 2022, 59(24): 2410009
    Download Citation