• Journal of Applied Optics
  • Vol. 44, Issue 4, 859 (2023)
Jiayu YANG1,2,3,4, Juntian ZENG1,2,3,4, Bangchao XI1,2,3,4, Guoqiang LIU1,2,3,4..., Shaolei HUANG1,2,3,4 and Dongxu ZHANG1,2,3,4,*|Show fewer author(s)
Author Affiliations
  • 1School of Public Health, Xiamen University, Xiamen 361102, China
  • 2State Key Laboratory of Molecular Vaccinology and Molecular Diagnostic, Xiamen University, Xiamen 361102, China
  • 3National Institute of Diagnostics and Vaccine Development in Infection Diseases, Xiamen University, Xiamen 361102, China
  • 4State Drug Administration Key Laboratory of Infectious Disease Detection Technology Research and Evaluation, Xiamen 361102, China
  • show less
    DOI: 10.5768/JAO202344.0403007 Cite this Article
    Jiayu YANG, Juntian ZENG, Bangchao XI, Guoqiang LIU, Shaolei HUANG, Dongxu ZHANG. Multiple real-time fluorescence detection system for rapid on-site nucleic acid detection[J]. Journal of Applied Optics, 2023, 44(4): 859 Copy Citation Text show less

    Abstract

    On-site rapid detection of nucleic acid has the advantages of convenience, simple operation, no need for special laboratories, and rapid reporting, which can be detected in various complex environments such as airports, community hospitals, customs and fields. A fluorescence detection system that can be applied to on-site rapid detection instruments of nucleic acid was established, including non-confocal orthogonal optical path and multi-channel detection integrated structure. The former has the characteristics of high signal-to-noise ratio, small and convenient. The latter has high switching efficiency and can meet multiple detection, and its embedded structure greatly reduces the fluorescence crosstalk between channels. The experimental results show that the detection limit of the system is lower than 1.6 μg/mL, the R2 value (coefficient of determination) of fluorescence detection gradient is greater than 0.99, and the coefficient of variance (CV) value of repeatability test does not exceed 1.27%. The inter-channel fluorescence crosstalk test shows that there is no crosstalk between channels, and the accuracy and stability of cytomegalovirus culture medium amplification experiment are good, which indicates that the system can effectively stimulate and collect fluorescence for multiple detection.