• Acta Photonica Sinica
  • Vol. 52, Issue 12, 1206002 (2023)
Han YANG, Kang XIE*, Tingkuo CHEN, Qianfa LIN..., Yibin ZHU, Ruiqi LI and Hongyan XIA**|Show fewer author(s)
Author Affiliations
  • School of Mechanical and Electrical Engineering,Guangdong University of Technology,Guangzhou 510006,China
  • show less
    DOI: 10.3788/gzxb20235212.1206002 Cite this Article
    Han YANG, Kang XIE, Tingkuo CHEN, Qianfa LIN, Yibin ZHU, Ruiqi LI, Hongyan XIA. U-shaped Microfiber Humidity Sensor Based on PVA Coating[J]. Acta Photonica Sinica, 2023, 52(12): 1206002 Copy Citation Text show less
    Schematic diagram of microfiber fabrication
    Fig. 1. Schematic diagram of microfiber fabrication
    Schematic diagram of the process of coated PVA
    Fig. 2. Schematic diagram of the process of coated PVA
    U-shaped sensor structure illustration
    Fig. 3. U-shaped sensor structure illustration
    U-shaped sensor electron microscope diagram
    Fig. 4. U-shaped sensor electron microscope diagram
    Transmittance spectrum of the sensor at 34% RH
    Fig. 5. Transmittance spectrum of the sensor at 34% RH
    Sensor humidity experimental equipment diagram
    Fig. 6. Sensor humidity experimental equipment diagram
    Spectrogram of resonant peak wavelength at 1 420~1 475 with humidity for sensor S-1 with a fit at 1 450~1 480 nm
    Fig. 7. Spectrogram of resonant peak wavelength at 1 420~1 475 with humidity for sensor S-1 with a fit at 1 450~1 480 nm
    Spectrogram of resonant peak wavelength at 1 430~1 488 with humidity for sensor S-2 with a fit at 1 464~1 488 nm
    Fig. 8. Spectrogram of resonant peak wavelength at 1 430~1 488 with humidity for sensor S-2 with a fit at 1 464~1 488 nm
    Spectral diagram of the resonant peak wavelength of sensor S-3 at 1 410~1 470 nm as a function of humidity
    Fig. 9. Spectral diagram of the resonant peak wavelength of sensor S-3 at 1 410~1 470 nm as a function of humidity
    Fitting diagram of resonant peak wavelength variation with humidity of sensor S-3 at 1 440~1 470 nm
    Fig. 10. Fitting diagram of resonant peak wavelength variation with humidity of sensor S-3 at 1 440~1 470 nm
    Spectrogram of resonant peak wavelength at 1 411~1 485 nm with humidity for sensor S-4 with a fit at 1 462~1 485 nm
    Fig. 11. Spectrogram of resonant peak wavelength at 1 411~1 485 nm with humidity for sensor S-4 with a fit at 1 462~1 485 nm
    Diagram of sensor S-2 humidity stability
    Fig. 12. Diagram of sensor S-2 humidity stability
    Spectral diagram and fitting of resonant peak wavelength variation with temperature of sensor S-1 at 1 450~1 480 nm
    Fig. 13. Spectral diagram and fitting of resonant peak wavelength variation with temperature of sensor S-1 at 1 450~1 480 nm
    SampleNumber of coatsWaist diameter/μmHumidity sensitivity/(pm/%RH)
    Sensor 109.080
    Sensor 239.68112.1
    Sensor 359.84146.1
    Sensor 4512.41101.2
    Table 1. Related parameters of the sensor
    Han YANG, Kang XIE, Tingkuo CHEN, Qianfa LIN, Yibin ZHU, Ruiqi LI, Hongyan XIA. U-shaped Microfiber Humidity Sensor Based on PVA Coating[J]. Acta Photonica Sinica, 2023, 52(12): 1206002
    Download Citation