• Optical Instruments
  • Vol. 41, Issue 6, 20 (2019)
Huaiyu FAN1,2, Junshan MA1,*, Yutang LIU2, and Caihong DU2
Author Affiliations
  • 1School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
  • 2Department of Medical Information Engineering, Jining Medical University, Rizhao 276826, China
  • show less
    DOI: 10.3969/j.issn.1005-5630.2019.06.004 Cite this Article
    Huaiyu FAN, Junshan MA, Yutang LIU, Caihong DU. The study on the automatic localization of the seed point in ultrasound breast tumor images[J]. Optical Instruments, 2019, 41(6): 20 Copy Citation Text show less
    The grayscale changes of the equalized images
    Fig. 1. The grayscale changes of the equalized images
    The process diagram of locating the seed
    Fig. 2. The process diagram of locating the seed
    类别本文方法文献[9]方法
    真阳性图像数目(TP5248
    假阳性图像数目(FP04
    真阴性图像数目(TN4749
    假阴性图像数目(FN64
    准确度((TP+TN)/(TP+TN+FP+FN)) 94.28%92.38%
    Table 1. Performance of the method
    阶段图1(a)耗时/s连续105幅图像平均耗时/s
    图像统一变换成512×512和灰度均衡阶段0.480.52
    定位种子点阶段2.682.45
    总计3.162.97
    Table 2. The consuming time in the stages for locating the seed piont in images
    Huaiyu FAN, Junshan MA, Yutang LIU, Caihong DU. The study on the automatic localization of the seed point in ultrasound breast tumor images[J]. Optical Instruments, 2019, 41(6): 20
    Download Citation