• Chinese Optics Letters
  • Vol. 22, Issue 12, 121201 (2024)
Shimiao Fan1,2, Wenfeng Fan2,3,*, Qi Yuan1,2, Xiaoping Li1,2..., Hongyu Pei1,2, Wei Quan2,3,4 and Lihong Duan2,3,**|Show fewer author(s)
Author Affiliations
  • 1School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
  • 2National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou 310023, China
  • 3Institute of Large-Scale Scientific Facility, Centre for Zero Magnetic Field Science, Beihang University, Beijing 100191, China
  • 4Hefei National Laboratory, Hefei 230088, China
  • show less
    DOI: 10.3788/COL202422.121201 Cite this Article Set citation alerts
    Shimiao Fan, Wenfeng Fan, Qi Yuan, Xiaoping Li, Hongyu Pei, Wei Quan, Lihong Duan, "Closed-loop atomic spin polarization detection based on EOAM modulation in K-Rb-21Ne co-magnetometers," Chin. Opt. Lett. 22, 121201 (2024) Copy Citation Text show less
    Schematic of the closed-loop atomic spin polarization detection system. EOAM, electro-optic amplitude modulator; CO, coupler; PL, polarizer; λ/2, half-wave plate; PBS, polarizing beam splitter; PD, photodiode.
    Fig. 1. Schematic of the closed-loop atomic spin polarization detection system. EOAM, electro-optic amplitude modulator; CO, coupler; PL, polarizer; λ/2, half-wave plate; PBS, polarizing beam splitter; PD, photodiode.
    Experimental setup of SERF co-magnetometer. TA, tapered amplifier; λ/4, quarter-wave plate; GL, Glan–Taylor prism.
    Fig. 2. Experimental setup of SERF co-magnetometer. TA, tapered amplifier; λ/4, quarter-wave plate; GL, Glan–Taylor prism.
    Testing of co-magnetometer angular velocity signal and scale factor based on closed-loop EOAM modulation detection system.
    Fig. 3. Testing of co-magnetometer angular velocity signal and scale factor based on closed-loop EOAM modulation detection system.
    Response testing of the closed-loop detection system to external perturbation. Case A: Using EOAM modulation only, with the closed-loop control system output turned off. Case B: The closed-loop EOAM modulation detection system designed in this Letter.
    Fig. 4. Response testing of the closed-loop detection system to external perturbation. Case A: Using EOAM modulation only, with the closed-loop control system output turned off. Case B: The closed-loop EOAM modulation detection system designed in this Letter.
    Comparison of inertial measurement sensitivity among different detection methods.
    Fig. 5. Comparison of inertial measurement sensitivity among different detection methods.
    Shimiao Fan, Wenfeng Fan, Qi Yuan, Xiaoping Li, Hongyu Pei, Wei Quan, Lihong Duan, "Closed-loop atomic spin polarization detection based on EOAM modulation in K-Rb-21Ne co-magnetometers," Chin. Opt. Lett. 22, 121201 (2024)
    Download Citation