• Journal of Applied Optics
  • Vol. 44, Issue 1, 219 (2023)
Hongqiang LI1,*, Quanhua MAO1, Zhixuan AN1, Zhilin LIN1..., Yingjie WANG1, Wentao MENG1, Zhiyue ZHU1, Zhen ZHANG2 and Prades Garcia Juan Daniel3|Show fewer author(s)
Author Affiliations
  • 1Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronics and Information Engineering, Tianjin Polytechnic University, Tianjin 300387, China
  • 2School of Computer Science and Technology, Tianjin Polytechnic University, Tianjin 300387, China
  • 3Department of Electronic and Biomedical Engineering,University of Barcelona, Barcelona E-08028, Spain
  • show less
    DOI: 10.5768/JAO202344.0108001 Cite this Article
    Hongqiang LI, Quanhua MAO, Zhixuan AN, Zhilin LIN, Yingjie WANG, Wentao MENG, Zhiyue ZHU, Zhen ZHANG, Prades Garcia Juan Daniel. Wearable fiber grating demodulation based on photonic integrated chip[J]. Journal of Applied Optics, 2023, 44(1): 219 Copy Citation Text show less

    Abstract

    In order to realize the application of fiber grating sensor in wearable system, a wearable fiber grating sensor demodulation system based on silicon-based photonic integrated chip was proposed. The photonic integrated chip based on Belgium iSiPP50G process was composed of 4×1 long wavelength VCSEL array, 1×8 array waveguide grating, 2×2 MMI coupler, 4×1 fiber grating coupler array, GE-on-SI waveguide photodetector, straight waveguide and curved waveguide, etc. After completing the gold wire bonding of the VCSEL light source and the optical fiber coupling package of the photonic integrated chip, a wristband demodulation circuit was designed to measure the human body temperature and heart sound signals in real time. The experimental results show that the dynamic wavelength detection range of the demodulation system is 1 540 nm~1 560 nm, the wavelength resolution is 0.08 pm, the demodulation accuracy is 5 pm, the temperature monitoring range is 35 ℃~42 ℃, and the error is ±0.1 ℃. It can detect the heart sound signal in the frequency range of 50 Hz~100 Hz, identify the first heart sound and the second heart sound, and calculate the cardiac cycle, heart rate, the first heart sound time limit, the second heart sound time limit and cardiac parameters.