• Optical Communication Technology
  • Vol. 48, Issue 1, 34 (2024)
SHAN Yiting1, ZHAO Lijuan1,2,3, ZHANG Zhijuan1, and HUANG Zimeng1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.13921/j.cnki.issn1002-5561.2024.01.007 Cite this Article
    SHAN Yiting, ZHAO Lijuan, ZHANG Zhijuan, HUANG Zimeng. Refractive index sensor with MIM waveguide structure coupled elliptical octagonal resonant cavity[J]. Optical Communication Technology, 2024, 48(1): 34 Copy Citation Text show less

    Abstract

    In order to improve the sensitivity of optical index sensor, a metal-medium-metal(MIM) waveguide coupled elliptic eight shape cavity is designed. Firstly, the principle and key performance index of the sensor structure are analyzed theoretically. Then, the simulation structure is constructed by using finite element analysis simulation software to study its sensing performance. The simulation results show that when a=540 nm, b=340 nm, g=10 nm, l=70 nm, the sensitivity of the designed sensor can reach 1 323 nm/RIU, and the corresponding quality factor can reach 16.
    SHAN Yiting, ZHAO Lijuan, ZHANG Zhijuan, HUANG Zimeng. Refractive index sensor with MIM waveguide structure coupled elliptical octagonal resonant cavity[J]. Optical Communication Technology, 2024, 48(1): 34
    Download Citation