- Chinese Optics Letters
- Vol. 20, Issue 3, 031702 (2022)
Abstract
1. Introduction
Cardiovascular disease is the leading killer of human beings during the past two decades. About two million people died from cardiovascular disease in 2019, constituting 16% of all global deaths (from the World Health Organization, 2020). Therein, atherosclerosis is one of the direct causes of various cardiovascular diseases[
In this paper, we demonstrate a new way to study ox-LDL by optical technology, which can change the secondary structure of ox-LDL by laser irradiation in an optofluidic resonator. The optofluidic resonator is a hollow-core metal-cladding waveguide (HCMW) constituted by three layers of slab glass. Based on free space coupling technology[
2. Materials and Methods
2.1. Experimental setup
The experimental setup (Fig. S3 in Supplementary Materials) consists of a CW laser (532 nm, 100 mW, MSL-FN-532, Changchun New Industries Optoelectronics Technology Co., Ltd., Changchun, China), an optical attenuator, two apertures, a synchronous rotator, a photoelectric detector, and an HCMW. The 532 nm laser beam was collimated by two apertures, and then an optical attenuator modulated the laser beam intensity. The HCMW filled with ox-LDL was illuminated for a time, and the intensity of reflected light was measured and recorded by a photoelectric detector.
Sign up for Chinese Optics Letters TOC. Get the latest issue of Chinese Optics Letters delivered right to you!Sign up now
The HCMW is a kind of optofluidic resonator, and the schematic of the structure is shown in Fig. 1(a). It includes five parts, and three layers in the middle constitute a 1 mm thick glass slab cavity. The top and bottom surfaces of the glass slab cavity are parallel (less than 4 in.). The upper silver film (about 35 nm thick) can couple the incident light into the HCMW. Another 300 nm thick silver film is utilized for a substrate layer in the bottom. The silver layers were fabricated by vacuum evaporation technology. After ultrasonic cleaning, the HCMW was coated with 300 nm Ag film on the bottom surface and 30 nm Ag film on the top surface in a vacuum evaporator (Beijing Technol Science Co., Ltd., Beijing, China). The Ag pellets were purchased from ZhongNuo Advanced Material Technology Co., Ltd. (Beijing, China). The purity of the Ag pellet is higher than 99.99%. The length and diameter of the Ag pellet are 5 mm and 2 mm, respectively. To prevent the Ag from evaporating into the cavity, both sides of the cavity should be covered during the vacuum evaporation.
Figure 1.Structure and properties of the HCMW. (a) HCMW 3D schematic diagram. (b) The COMSOL simulation image of the HCMW. (c) The reflectivity simulation image of the HCMW with different imaginary parts of dielectric coefficient εi (from 0 to 1 × 105).
Due to the thin metal coupling layer and the small effective refractive index, the incident light can be coupled from the free space into the guiding layer without any additional coupler such as a grating or high-index prism[
Human ox-LDL used in experiments was purchased from Dalian Meilun Biotech Co., Ltd. (Dalian, China). The purity of ox-LDL is more than 98%, and the concentration of ox-LDL is 2.2 mg/mL. There are traces of phosphate buffered saline (PBS) and ethylenediaminetetraacetic acid (EDTA)-Na2 in ox-LDL. Ox-LDL and LDL are key risk factors for the genesis of atherosclerosis plaque, they can transport cholesterol, and ox-LDL-cholesterol migrates into coronary artery walls, where they then accumulate under coronary artery walls, causing atherosclerosis[
Figure 2.Variation of ox-LDL in different light fields. (a) and (b) Structures of LDL and ox-LDL, respectively. Meanwhile, the detailed components are described in Supplementary Materials. (c) HCMW 3D schematic diagram. (d) Quartz cuvette. (e) The ox-LDL, which is illuminated in the HCMW. (f) The ox-LDL, which is illuminated in the cuvette. (g) The experimental reflection spectra for ox-LDL with different time exposures to the laser in the HCMW. (h) The experimental reflection spectra for ox-LDL with different time exposures to the laser in the cuvette.
2.2. Ox-LDL ELISA
The ox-LDL ELISA reagent kit (48T) was purchased from Shanghai Enzyme-linked Biotechnology Co., Ltd. (Shanghai, China). As shown in Fig. 3(a), 48 well microplates had been precoated with captured ox-LDL antibodies. Then, 100 µL of ox-LDL without illumination and ox-LDL after 40 min illumination were added into the wells, respectively. Meanwhile, one negative sample was included in each run as a control. Then, 100 µL of the enzyme-conjugated antibody was added into each well. After incubating at 37°C for 1 h, the plate was washed five times, and the substrate was added (100 µL/well). The plate was intubated in dark at 37°C for 15 min again. The color reaction was stopped by adding 100 µL/well of stopping solution. Color intensity was measured by using a microplate reader with a 450 nm filter. The optic density (OD) values of the test samples were “blank corrected” by subtracting the OD value of the negative control. The ELISA experiments were carried out 10 times. The microplate reader ARM-100 was purchased from Hangzhou Allsheng Instruments Co., Ltd. (Hangzhou, China). The 450 nm filter was chosen.
Figure 3.ELISA experiment of ox-LDL after laser illumination. (a) Schematic illustration of ELISA experiment. (b) Optical density comparison of unilluminated ox-LDL and 40 min illuminated ox-LDL in the HCMW, respectively.
2.3. NMR, micro-IR, and circular dichroism
The 1H nuclear magnetic resonance (NMR) spectra were recorded on a Bruker Avance Neo 700 spectrometer (700 MHz, Bruker, Rheinstetten, Germany). The spectra were recorded with the following acquisition parameters: temperature, 298 K; sweep width, 14,705.883 Hz, frequency of observing channel, 700.23 MHz; acquisition time, 1.114112 s; relaxation delay,
Before recording micro-infrared (IR) spectra, the sample was freeze-dried[
Circular dichroism (CD) spectra were recorded on a Jasco J-1500 CD spectrometer (Jasco Corporation, Tokyo, Japan). Diluent 20 µL ox-LDL (2.2 mg/mL) was both illuminated and unilluminated with PBS (pH 7.4) to a concentration of 88 µg/mL. The illuminated and unilluminated ox-LDL samples were injected in micro cuvettes, respectively. The measurement range was set to 195–350 nm, the cell length to 10 nm, the data pitch to 0.5 nm, scanning speed to 50 nm/min, and bandwidth to 2 nm. The calculation of the simulation curves and analysis of secondary structures were supported by Spectra Manager II software (Jasco Corporation, Tokyo, Japan).
3. Results
3.1. Ox-LDL illuminated in HCMW and cuvette
Ox-LDL was injected into the HCMW and cuvette by using electronically controlled micro-syringe channel 1 and channel 2, respectively, as shown in Figs. 2(c)–2(f). The 532 nm CW laser (30 mW) was used to illuminate ox-LDL in the HCMW and cuvette. The intensity of reflected light of the HCMW filled with the ox-LDL solution was recorded by a photoelectric detector during the irradiation time. The curve of reflectivity measured from the HCMW tended to be flat after 45 min of laser beam illumination and achieved dynamic equilibrium in the same interval of reflectivity after another 40 min irradiation by the same laser beam, as shown in Fig. 2(g). Then, ox-LDL injected into the cuvette was illuminated by the same laser beam, and the illuminated ox-LDL in the cuvette was transferred into the HCMW to measure the intensity of reflected light. The measured reflectivity curves of the HCMWs, which were filled with 5 min (red), 45 min (blue), and 90 min illuminated ox-LDL (green) are presented in Fig. 2(h), respectively, which show little change. Compared with HCMW experimental data, the variation of reflectivity implied the structure of ox-LDL illuminated in HCMW changed after the laser irradiation.
3.2. Ox-LDL ELISA experiment
OD values represent the ox-LDL binding rate of ox-LDL antibody. A microplate reader was used to measure the OD values of both illuminated ox-LDL and unilluminated ox-LDL. OD values of ox-LDL without illumination and after 40 min illumination are presented in Fig. 3(b). All 10 times ELISA experiment results demonstrate that the OD value of the illuminated ox-LDL well is higher than without being illuminated in the same run. The average OD value of unilluminated ox-LDL wells is 0.2023, the average OD value of 40 min illuminated ox-LDL wells is 0.2267, while the value of 40 min illuminated ox-LDL wells increases 12.15% on average, as shown in Table 1. The results of the ELISA experiment indicate that the illuminated ox-LDL in the HCMW can increase the binding rate of ox-LDL and antibodies.
Group No. | Before | After | Rate of Increase (%) |
---|---|---|---|
1 | 0.216 | 0.253 | 17.20 |
2 | 0.175 | 0.192 | 9.70 |
3 | 0.201 | 0.222 | 10.40 |
4 | 0.141 | 0.197 | 39.70 |
5 | 0.271 | 0.282 | 4.10 |
6 | 0.172 | 0.178 | 3.40 |
7 | 0.182 | 0.190 | 4.40 |
8 | 0.217 | 0.224 | 3.20 |
9 | 0.211 | 0.282 | 25.20 |
10 | 0.237 | 0.247 | 4.20 |
Average | 0.2023 | 0.2267 | 12.15 |
Table 1. Experiment Data of ox-LDL ELISA, Both Exposed and Unexposed
3.3. Comparison of different experiment parameters
Some parameters may influence the experiment results, the wavelength of the laser, the power of the beam, and the time of irradiation, for instance. Therefore, we compared the results with different irradiation parameters in Fig. 4. As shown in Fig. 4(a), the reflectivity spectra of different irradiation times are presented. The results demonstrate that the slope of measured ATR curves of incident light becomes smaller and tends to oscillate in a small range around a value during the first 30 min of laser beam irradiation (CW, 532 nm, 30 mW). Eventually, the ATR keeps dynamic equilibrium and oscillates in the same interval. As shown in Fig. 4(b), the variation of ATR peak
Figure 4.Comparison of different experiment parameters. (a) The measured reflection spectra of the HCMW filled with different laser continuous irradiation time ox-LDL. (b) Image of ΔR with different laser irradiation time. (c) and (d) The measured reflection spectra of the HCMW filled with ox-LDL under the irradiation of 5 mW and 50 mW laser beams, respectively. (e) and (f) The measured reflection spectra of the HCMW filled with ox-LDL illuminated by 473 nm and 532 nm lasers, respectively.
4. Discussion
4.1. Ox-LDL change
To confirm the cause of binding rate increment of the ox-LDL antibody and 40 min illuminated ox-LDL, the 1H NMR spectra were measured as shown in Figs. 5(a) and 5(b). In terms of the position of peaks and ratio of peak intensity in two spectra, the primary structures of unilluminated ox-LDL and 40 min illuminated ox-LDL are not different. Likewise, the measured micro-IR spectra indicate the same results as the NMR spectra. As shown in Figs. 5(c) and 5(d), the peak positions and peak ratios in the two spectra are nearly the same, which implies that the organo-functional groups of unilluminated and 40 min illuminated ox-LDL are not different. According to NMR and micro-IR spectra, the primary structure of ox-LDL is not changed under the laser beam illumination in the HCMW. Therefore, the CD spectra were recorded to detect the change of ox-LDL’s secondary structures. CD records the absorption intensity difference of left circularly polarized light and right circularly polarized light[
Figure 5.Analysis of ox-LDL structures variation after laser irradiation. (a) and (b) 1H NMR spectra of ox-LDL before laser irradiation and after 40 min irradiation in the HCMW, respectively. (c) and (d) Micro-IR spectra of ox-LDL before laser irradiation and after 40 min illumination in the HCMW, respectively. (e) and (f) Circular dichroism (CD) spectra of both states of ox-LDL in the HCMW, respectively: CD (black), HT (red), and absorption of solution (blue).
Figure 6.(a) and (b) Experimental CD spectra (black), software simulation curves (red), and the difference between the measured CD spectra and software simulation curves (blue).
Based on the software simulation and analysis, the content ratios of
4.2. Summary
In this work, we report a photocatalysis experiment reacting in the HCMW, which changed the secondary structures of ox-LDL. The HCMW provides a strong electromagnetic field, which can support the reactions while the cuvette cannot. According to the CD spectra, the significant content ratio variations of
References
[1] J. Sanz, Z. Fayad. Imaging of atherosclerotic cardiovascular disease. Nature, 451, 953(2008).
[2] J. L. Aldons. Atherosclerosis. Nature, 407, 233(2000).
[3] P. Libby, P. Ridker, G. Hansson. Progress and challenges in translating the biology of atherosclerosis. Nature, 473, 317(2011).
[4] S. Tatsuya, K. Noriaki, A. Takuma, M. Hideaki, H. Hajime, A. Yuichi, T. Takeshi, M. Soichi, K. Yoshimoto, K. Toru, M. Tomoh. An endothelial receptor for oxidized low-density lipoprotein. Nature, 386, 73(1997).
[5] S. Parthasarathy, A. Raghavamenon, M. O. Garelnabi, N. Santanam. Oxidized low-density lipoprotein. Methods Mol. Biol., 610, 403(2010).
[6] M. Tamminen, G. Mottino, J. Qiao, J. Breslow, J. Frank. Ultrastructure of early lipid accumulation in ApoE-deficient mice. Arterioscler. Thromb. Vasc. Biol., 19, 847(1999).
[7] K. Nakajima, T. Nakano, A. Tanaka. The oxidative modification hypothesis of atherosclerosis: the comparison of atherogenic effects on oxidized LDL and remnant lipoproteins in plasma. Clinica Chimica Acta, 367, 36(2006).
[8] M. Quinn, S. Parthasarathy, L. Fong, D. Steinberg. Oxidatively modified low density lipoproteins: a potential role in recruitment and retention of monocyte/macrophages during atherogenesis. Proc. Natl. Acad. Sci. U. S. A., 84, 2995(1987).
[9] S. Mitra, A. Deshmukh, R. Sachdeva, J. Lu, J. L. Mehta. Oxidized low-density lipoprotein and atherosclerosis implications in antioxidant therapy. Am. J. Med. Sci., 342, 135(2011).
[10] T. Andreja, I. Resanovic, S. Julijana, R. Djordje, A. M. Shaker, C. M. Desanka, J. Danimir, R. I. Esma. Oxidized low-density lipoprotein as a biomarker of cardiovascular diseases. Crit. Rev. Clin. Lab. Sci., 52, 70(2015).
[11] S. Choi, R. Harkewicz, J. H. Lee, A. Boullier, F. Almazan, A. C. Li, J. L. Witztum, Y. S. Bae, I. M. Yury. Lipoprotein accumulation in macrophages via toll-like receptor-4-dependent fluid phase uptake. Circ. Res., 104, 1355(2009).
[12] R. Carnevale, S. Bartimoccia, C. Nocella, D. S. Serena, L. Lorenzo, I. Giulio, L. Elisabetta, B. Valentina, D. B. Maria, D. M. Luigi, P. Pasquale, V. Francesco. LDL oxidation by platelets propagates platelet activation via an oxidative stress-mediated mechanism. Atherosclerosis, 237, 108(2014).
[13] G. Obermayer, T. Afonyushkin, C. J. Binder. Oxidized low-density lipoprotein in inflammation-driven thrombosis. J. Thromb. Haemost., 16, 418(2018).
[14] S. A. Thorne, S. E. Abbot, P. G. Winyard, D. R. Blake, P. G. Mills. Extent of oxidative modification of low density lipoprotein determines the degree of cytotoxicity to human coronary artery cells. Heart, 75, 11(1996).
[15] H. Kataoka, N. Kume, S. Miyamoto, M. Minami, M. Morimoto, K. Hayashida, N. Hashimoto, T. Kita. Oxidized LDL modulates Bax/Bcl-2 through the lectinlike Ox-LDL receptor-1 in vascular smooth muscle cells. Arterioscler. Thromb. Vasc. Biol., 21, 955(2001).
[16] F. Sigala, K. Athanassios, S. Paraskevi, F. Konstantinos, M. Sophia, K. I. Efstathios, G. G. Vassilis, A. Ioanna. Oxidized LDL in human carotid plaques is related to symptomatic carotid disease and lesion instability. J. Vasc. Surg., 52, 704(2010).
[17] S. M. Marcovina, F. Crea, J. Davignon, J. C. Kaski, W. Koenig, U. Landmesser, P. L. Pieri, M. J. Schulz, L. J. Shaw, J. Sobesky. Biochemical and bioimaging markers for risk assessment and diagnosis in major cardiovascular diseases: a road to integration of complementary diagnostic tools. J. Intern. Med., 261, 214(2007).
[18] H. Itabe, M. Ueda. Measurement of plasma oxidized low-density lipoprotein and its clinical implications. J. Atheroscler. Thromb., 14, 1(2007).
[19] A. Sato, Y. Yamazaki, K. Ebina. A method for in vitro measurement of oxidized low-density lipoprotein in blood, using its antibody, fluorescence-labeled heptapeptide and polyethylene glycol. J. Fluoresc., 27, 1985(2017).
[20] A. Zinellu, S. Salvatore, G. Franca, L. Fiorenza, P. Valeria, M. P. Giovanni, T. Bruna, D. Luca, C. Ciriaco. Applications on the monitoring of oxidative modification of LDL by capillary electrophoresis: a comparison with spectrophotometer assay. Talanta, 64, 428(2004).
[21] J. Stocks, N. Miller. Analysis of apolipoproteins and lipoproteins by capillary electrophoresis. Electrophoresis, 20, 2118(1999).
[22] H. Hinterwirth, G. Stübiger, W. Lindner, M. Lämmerhofer. Gold nanoparticle-conjugated anti-oxidized low-density lipoprotein antibodies for targeted lipidomics of oxidative stress biomarkers. Anal. Chem., 85, 8376(2013).
[23] E. Haller, G. Stübiger, D. Lafitte, W. Lindner, M. Lämmerhofer. Chemical recognition of oxidation-specific epitopes in low-density lipoproteins by a nanoparticle based concept for trapping, enrichment, and liquid chromatography-tandem mass spectrometry analysis of oxidative stress biomarkers. Anal. Chem., 86, 9954(2014).
[24] H. Dai, L. Yuan, C. Yin, Z. Cao, X. Chen. Direct visualizing the spin Hall effect of light via ultrahigh-order modes. Phys. Rev. Lett., 124, 053902(2020).
[25] H. Li, Z. Cao, H. Lu, Q. Shen. Free-space coupling of a light beam into a symmetrical metal-cladding optical waveguide. Appl. Phys. Lett., 83, 2757(2003).
[26] C. Yin, X. Kan, K. Guo, T. Wang, J. Xu, Q. Han, J. Wu, Z. Cao. Highly twisted M-line of a vortex beam due to the coupling of ultrahigh-order modes. Chin. Opt. Lett., 19, 071403(2021).
[27] G. Hansson. Mechanisms of disease-inflammation, atherosclerosis, and coronary artery disease. N. Engl. J. Med., 352, 1685(2005).
[28] A. Halil, P. Bahar. Effect of purification, dehydration, and coagulation processes on the optical parameters of biological tissues. Chin. Opt. Lett., 19, 011701(2021).
[29] Y. H. Chen, J. T. Yang, K. H. Chau. Determination of the helix and β form of proteins in aqueous solution by circular dichroism. Biochemistry, 13, 3350(1974).