• Journal of Applied Optics
  • Vol. 45, Issue 6, 1170 (2024)
Zhentao WU1,2, Rui ZHANG2,3, Wenyue LI4, Yanxiang CHANG4..., Yaqi WANG2,5, Shuai YANG2,5, Peng XUE2,5 and Zhibin WANG1,2,*|Show fewer author(s)
Author Affiliations
  • 1North University of China, School of Instrument and Electronics, Taiyuan Shanxi 030051, China
  • 2Technology Innovation Center of Shanxi Provincial for Intelligent Microwave Photoelectric, North University of China, Taiyuan, Shanxi 030051, China
  • 3North University of China, School of information and communication engineering, Taiyuan Shanxi 030051, China
  • 4Military Representative Office of military equipment department in Beijing, Taiyuan Shanxi 030051, China
  • 5North University of China, School of electrical and control engineering, Taiyuan Shanxi 030051, China
  • show less
    DOI: 10.5768/JAO202445.0602001 Cite this Article
    Zhentao WU, Rui ZHANG, Wenyue LI, Yanxiang CHANG, Yaqi WANG, Shuai YANG, Peng XUE, Zhibin WANG. Rapid extraction algorithm of laser alarm spot center based on projection segmentation[J]. Journal of Applied Optics, 2024, 45(6): 1170 Copy Citation Text show less

    Abstract

    In order to solve the problems of missed alarm and slow response speed in the existing laser alarm system due to untimely data processing, a rapid extraction algorithm of spot center based on projection segmentation was proposed. According to the characteristics of the horizontal uniform distribution of spots at all levels in the diffraction images, a method of rapid extraction was proposed by projecting to the coordinate axis and calculating the center coordinates of light spot respectively. The proposed algorithm was deployed to the FPGA hardware system, so as to enable the alarm system to complete the task of extracting the center coordinates of the spot within a frame image transmission cycle, which improved the image processing efficiency and realized the efficient alarming. Experiments show that the maximum error of spot center coordinate extraction is 1 pixel, and the response time of the alarm system is 17.453 ms. By optimizing the image processing algorithm, the response time of the alarm equipment is shortened, and the rapid and accurate alarm of the incoming laser is realized.
    Zhentao WU, Rui ZHANG, Wenyue LI, Yanxiang CHANG, Yaqi WANG, Shuai YANG, Peng XUE, Zhibin WANG. Rapid extraction algorithm of laser alarm spot center based on projection segmentation[J]. Journal of Applied Optics, 2024, 45(6): 1170
    Download Citation