• Spectroscopy and Spectral Analysis
  • Vol. 40, Issue 10, 3205 (2020)
Xiao-peng SUN*, Rui-jun MA, Yu CHEN, Huan-yi ZHEN, and Chuang-li MA
Author Affiliations
  • College of Engineering, South China Agricultural University, Guangzhou 510642, China
  • show less
    DOI: 10.3964/j.issn.1000-0593(2020)10-3205-06 Cite this Article
    Xiao-peng SUN, Rui-jun MA, Yu CHEN, Huan-yi ZHEN, Chuang-li MA. Experimental Study on Determination of Trisodium Phosphate Concentration in Water Based on Spectral Technique[J]. Spectroscopy and Spectral Analysis, 2020, 40(10): 3205 Copy Citation Text show less
    Original absorption spectra of trisodium phosphatein by using three types experimental system(a): Pulse xenon lamp with 100 mm optical path; (b): Deuterium halide lamp with 100 mm optical path;(c): Deuterium halide lamp with 10 mm optical path
    Fig. 1. Original absorption spectra of trisodium phosphatein by using three types experimental system
    (a): Pulse xenon lamp with 100 mm optical path; (b): Deuterium halide lamp with 100 mm optical path;(c): Deuterium halide lamp with 10 mm optical path
    Absorption spectra of trisodium phosphate after S-G pretreatment bu using three types experimental system(a): Pulse xenon lamp with 100 mm optical path; (b): Deuterium halide lamp with 100 mm optical path; (c): Deuterium halide lamp with 10 mm optical path
    Fig. 2. Absorption spectra of trisodium phosphate after S-G pretreatment bu using three types experimental system
    (a): Pulse xenon lamp with 100 mm optical path; (b): Deuterium halide lamp with 100 mm optical path; (c): Deuterium halide lamp with 10 mm optical path
    MEAN-STD distribution of MCCV method(a): Experiment of pulse xenon lamp with 100 mm optical path; (b): Experiment of deuterium halide lamp with 100 mm optical path; (c): Experiment of deuterium halide lamp with 10 mm optical path
    Fig. 3. MEAN-STD distribution of MCCV method
    (a): Experiment of pulse xenon lamp with 100 mm optical path; (b): Experiment of deuterium halide lamp with 100 mm optical path; (c): Experiment of deuterium halide lamp with 10 mm optical path
    The correlation coefficient between absorbance and wavelength of trisodium phosphate for three types experiments(a): Pulse xenon lamp with 100 mm optical path; (b): Deuterium halide lamp with 100 mm optical path;(c): Deuterium halide lamp with 10 mm optical path
    Fig. 4. The correlation coefficient between absorbance and wavelength of trisodium phosphate for three types experiments
    (a): Pulse xenon lamp with 100 mm optical path; (b): Deuterium halide lamp with 100 mm optical path;(c): Deuterium halide lamp with 10 mm optical path
    数据来源预处理方法因子数预测集
    RP2RMSEPRPD
    100 mm
    光程比色
    皿脉冲氙
    灯实验
    移动平均平滑50.996 30.816 317.092 1
    S-G卷积平滑50.996 50.796 217.523 6
    一阶导数60.995 90.865 916.113 1
    二阶导数90.950 92.994 04.660 1
    100 mm
    光程比色
    皿氘卤灯
    实验
    移动平均平滑60.997 80.561 922.136 9
    S-G卷积平滑60.997 90.549 022.657 1
    一阶导数50.996 40.727 617.095 6
    二阶导数60.988 01.321 59.412 6
    10 mm
    光程比色
    皿氘卤灯
    实验
    移动平均平滑50.995 60.830 915.632 9
    S-G卷积平滑50.995 70.826 215.721 8
    一阶导数40.991 61.154 511.251 1
    二阶导数40.857 44.748 82.735 3
    Table 1. PLS model results of three types experiments with different pretreatment methods
    序号数据来源因子数样本数变量数校正集预测集
    RC2RMSECRP2RMSEPRPD
    a100 mm光程比色皿
    脉冲氙灯实验
    剔除前5653200.999 31.093 80.996 50.796 217.523 6
    剔除后5593200.999 30.794 30.996 90.758 218.401 9
    b100 mm光程比色皿
    氘卤灯实验
    剔除前6653200.999 40.963 90.997 90.549 022.657 1
    剔除后6573200.999 50.800 70.998 00.544 922.827 6
    c10 mm光程比色皿
    氘卤灯实验
    剔除前5654280.997 81.909 50.995 70.826 215.721 8
    剔除后5584280.999 30.869 60.996 50.743 517.470 6
    Table 2. PLS model results of all band data of trisodium phosphate before and after singular sample removed
    序号数据来源特征波长
    /nm
    因子数校正集预测集
    RC2RMSECRP2RMSEPRPD
    a100 mm光程比色皿
    脉冲氙灯实验
    214.099 8
    258.528 9
    20.992 72.658 60.970 52.321 66.009 8
    b100 mm光程比色皿
    氘卤灯实验
    218.837 1
    309.760 6
    20.995 32.455 60.972 61.992 66.242 5
    c10 mm光程比色皿
    氘卤灯实验
    204.66
    316.17
    20.982 24.264 30.962 52.436 85.330 5
    Table 3. Characteristic wavelengths of trisodium phosphate and its PLS model results
    序号数据来源变量数因子数校正集预测集
    RC2RMSECRP2RMSEPRPD
    a100 mm光程比色皿
    脉冲氙灯实验
    4870.999 80.472 50.998 00.599 123.288 8
    b100 mm光程比色皿
    氘卤灯实验
    4870.999 70.670 00.996 50.708 017.568 8
    c10 mm光程比色皿
    氘卤灯实验
    6160.999 40.800 30.994 10.967 313.428 5
    Table 4. Characteristic band of trisodium phosphate and its PLS model results
    Xiao-peng SUN, Rui-jun MA, Yu CHEN, Huan-yi ZHEN, Chuang-li MA. Experimental Study on Determination of Trisodium Phosphate Concentration in Water Based on Spectral Technique[J]. Spectroscopy and Spectral Analysis, 2020, 40(10): 3205
    Download Citation