• Laser & Optoelectronics Progress
  • Vol. 60, Issue 2, 0212002 (2023)
Zhibo Leng1,2 and Xin Jin2,*
Author Affiliations
  • 1School of Biomedical Engineering, Division of Life Sciences and Medicine, University of Science and Technology of China, Suzhou 215000, Jiangsu, China
  • 2Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215000, Jiangsu, China
  • show less
    DOI: 10.3788/LOP212862 Cite this Article Set citation alerts
    Zhibo Leng, Xin Jin. Symmetrical Fringe Projection Measurement Method Based on Window Matching[J]. Laser & Optoelectronics Progress, 2023, 60(2): 0212002 Copy Citation Text show less
    Dual-frequency method
    Fig. 1. Dual-frequency method
    Three-frequency method
    Fig. 2. Three-frequency method
    Symmetrical phase and wrapped phase
    Fig. 3. Symmetrical phase and wrapped phase
    Window matching
    Fig. 4. Window matching
    Measurement grating diagrams. (a)-(d) High-frequency four-step phase shifting diagram; (e)-(f) symmetrical fringe diagram; (g)-(j) low-frequency four-step phase shifting diagram; (k)-(n) single-frequency four-step phase shifting diagram
    Fig. 5. Measurement grating diagrams. (a)-(d) High-frequency four-step phase shifting diagram; (e)-(f) symmetrical fringe diagram; (g)-(j) low-frequency four-step phase shifting diagram; (k)-(n) single-frequency four-step phase shifting diagram
    Phase results. (a) Wrapped phase; (b) symmetrical phase; (c) fringe order
    Fig. 6. Phase results. (a) Wrapped phase; (b) symmetrical phase; (c) fringe order
    Comparison of absolute phase and error. (a)-(c) Absolute phase; (d)-(f) phase error
    Fig. 7. Comparison of absolute phase and error. (a)-(c) Absolute phase; (d)-(f) phase error
    Three-dimensional point cloud. (a) Dual-frequency method; (b) three-frequency method; (c) proposed method
    Fig. 8. Three-dimensional point cloud. (a) Dual-frequency method; (b) three-frequency method; (c) proposed method
    SNRRMSE /rad
    Dual-frequency methodProposed method
    300.89540.0274
    252.74240.0486
    204.64450.0867
    Table 1. Test results of RMSE
    ParameterDual-frequency methodThree-frequency methodProposed method
    Error /mm0.08100.00750.0077
    Table 2. Point cloud accuracy comparison