• Journal of Applied Optics
  • Vol. 42, Issue 5, 941 (2021)
Dingrui WANG1, Xiao DENG1,2,*, Jun ZHANG1, Xinshuo LU1..., Chao DU1, Li ZHANG1 and Lin ZHANG3|Show fewer author(s)
Author Affiliations
  • 1College of Physics and Optoelectronics, Taiyuan University of Technology, Taiyuan 030024, China
  • 2Key Laboratory of Advanced Transducers and Intelligent Control System (Ministry of Education and Shanxi Province), Taiyuan University of Technology, Taiyuan 030024, China
  • 3College of Architecture, Taiyuan University of Technology, Taiyuan 030024, China
  • show less
    DOI: 10.5768/JAO202142.0508003 Cite this Article
    Dingrui WANG, Xiao DENG, Jun ZHANG, Xinshuo LU, Chao DU, Li ZHANG, Lin ZHANG. High spatial resolution distributed optical fiber temperature measurement system for ice cover profile[J]. Journal of Applied Optics, 2021, 42(5): 941 Copy Citation Text show less
    Overall structure of system
    Fig. 1. Overall structure of system
    Determination of spatial resolution
    Fig. 2. Determination of spatial resolution
    Experimental platform for testing spatial resolution improvement
    Fig. 3. Experimental platform for testing spatial resolution improvement
    Experimental platform for freezing and melting of river ice cover
    Fig. 4. Experimental platform for freezing and melting of river ice cover
    Temperature response of fiber rings with different lengths
    Fig. 5. Temperature response of fiber rings with different lengths
    Spatial resolution of system
    Fig. 6. Spatial resolution of system
    Deconvolution algorithm
    Fig. 7. Deconvolution algorithm
    Freezing and melting process of ice cover
    Fig. 8. Freezing and melting process of ice cover
    温度/℃空间分辨率/m
    101.22
    51.26
    01.27
    −51.26
    −101.31
    −151.38
    −201.36
    −251.25
    −301.30
    Table 1. Test repeatability of spatial resolution
    实际 温度 校正前 温度 校正后 温度 校正前 误差 校正后 误差
    15.3218.7715.043.450.28
    9.8916.179.736.280.16
    4.9112.345.127.430.21
    0.258.54−0.238.290.48
    −4.765.98−5.2010.740.44
    −9.703.09−10.0012.790.30
    −14.870.56−15.2615.430.39
    −19.88−2.90−19.8716.980.01
    −24.90−6.17−25.1518.730.25
    −29.96−9.21−29.7920.750.17
    Table 2. Error of temperature before and after correction and actual temperature ℃
    Dingrui WANG, Xiao DENG, Jun ZHANG, Xinshuo LU, Chao DU, Li ZHANG, Lin ZHANG. High spatial resolution distributed optical fiber temperature measurement system for ice cover profile[J]. Journal of Applied Optics, 2021, 42(5): 941
    Download Citation