• High Power Laser and Particle Beams
  • Vol. 36, Issue 8, 084001 (2024)
Yonghong Guan, Zhipeng Tang, Yuefeng Jing, Caihua Wei, and Jin Liu
Author Affiliations
  • Institute of Fluid Physics, CAEP, Mianyang 621900, China
  • show less
    DOI: 10.11884/HPLPB202436.240071 Cite this Article
    Yonghong Guan, Zhipeng Tang, Yuefeng Jing, Caihua Wei, Jin Liu. Inconsistency response correction method for scintillator array in flash radiography[J]. High Power Laser and Particle Beams, 2024, 36(8): 084001 Copy Citation Text show less
    Structure diagram and principle diagram of scintillator array
    Fig. 1. Structure diagram and principle diagram of scintillator array
    Examples of experiment image, empty field image and dark current image
    Fig. 2. Examples of experiment image, empty field image and dark current image
    Examples of empty field images and dark current image collected before the experiment
    Fig. 3. Examples of empty field images and dark current image collected before the experiment
    Experimental image with scintillator array artifacts and the image after correction
    Fig. 4. Experimental image with scintillator array artifacts and the image after correction
    Artifact of corrected image in high vibration environment
    Fig. 5. Artifact of corrected image in high vibration environment
    Direct correction using mismatched empty field image
    Fig. 6. Direct correction using mismatched empty field image
    Corrected images using empty field images with different displacements
    Fig. 7. Corrected images using empty field images with different displacements
    Relationship curve between standard deviation data of corrected image and displacement amount of empty field image
    Fig. 8. Relationship curve between standard deviation data of corrected image and displacement amount of empty field image
    Comparison of corrected images after different displacement of empty field image
    Fig. 9. Comparison of corrected images after different displacement of empty field image
    Relationship curve between the standard deviation data of the corrected image and the displacement amount of the empty field image
    Fig. 10. Relationship curve between the standard deviation data of the corrected image and the displacement amount of the empty field image
    Yonghong Guan, Zhipeng Tang, Yuefeng Jing, Caihua Wei, Jin Liu. Inconsistency response correction method for scintillator array in flash radiography[J]. High Power Laser and Particle Beams, 2024, 36(8): 084001
    Download Citation