• Acta Optica Sinica
  • Vol. 43, Issue 3, 0315001 (2023)
Zhuocan Jiang1,2, Yueqiang Zhang1,2,*, Biao Hu1,2, Xiaolin Liu1,2, and Qifeng Yu1,2
Author Affiliations
  • 1Institute of Intelligent Optical Measurement and Detection, Shenzhen University, Shenzhen 518000, Guangdong, China
  • 2College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518000, Guangdong, China
  • show less
    DOI: 10.3788/AOS221451 Cite this Article Set citation alerts
    Zhuocan Jiang, Yueqiang Zhang, Biao Hu, Xiaolin Liu, Qifeng Yu. A Calibration Method for Extrinsic Parameters of Monocular Laser Speckle Projection System[J]. Acta Optica Sinica, 2023, 43(3): 0315001 Copy Citation Text show less
    Flow chart of calibration for proposed method
    Fig. 1. Flow chart of calibration for proposed method
    Schematic of calibration board
    Fig. 2. Schematic of calibration board
    Speckle image of calibration board
    Fig. 3. Speckle image of calibration board
    Fitting of the projector's optical center
    Fig. 4. Fitting of the projector's optical center
    Experiment system
    Fig. 5. Experiment system
    Depth map of the planar board
    Fig. 6. Depth map of the planar board
    Displacement measurement results of the planar board
    Fig. 7. Displacement measurement results of the planar board
    Speckle image of standard spheres
    Fig. 8. Speckle image of standard spheres
    3D model of the right sphere in Fig. 8
    Fig. 9. 3D model of the right sphere in Fig. 8
    Experimental images of the fifth group. (a) Speckle image of camera; (b) virtual speckle image of projector
    Fig. 10. Experimental images of the fifth group. (a) Speckle image of camera; (b) virtual speckle image of projector
    Test object and its 3D reconstruction results. (a) Color image; (b) speckle image; (c) reconstruction result of Astra-Pro;(d) reconstruction result of proposed method
    Fig. 11. Test object and its 3D reconstruction results. (a) Color image; (b) speckle image; (c) reconstruction result of Astra-Pro;(d) reconstruction result of proposed method
    Standard sphereActual radius /mmMeasured radius /mmAbsolute error /mmRMS /mm
    Right sphere28.562528.65410.09160.1182
    Left sphere28.562528.68990.12740.1346
    Table 1. Radius measurement data and error of standard spheres in Fig. 8
    Order of experimentsAstra-ProProposed methodMeasured error of fitting planes /mm
    Average error /mmDepth distribution range /mmAverage error /mmDepth distribution range /mm
    10.71704.79110.02420.23390.171
    20.15455.03020.02650.25300.053
    30.70904.91080.02970.28600.126
    40.59554.61010.03330.31660.165
    50.54334.31690.03790.36480.230
    60.61565.24440.04150.40350.215
    Table 2. Comparison between Astra-Pro and proposed method
    Zhuocan Jiang, Yueqiang Zhang, Biao Hu, Xiaolin Liu, Qifeng Yu. A Calibration Method for Extrinsic Parameters of Monocular Laser Speckle Projection System[J]. Acta Optica Sinica, 2023, 43(3): 0315001
    Download Citation