    Abstract

    During the development of a charge-coupled device (CCD) imaging circuit, it is necessary to adjust the parameters of the CCD’s driving signal and repeatedly test the full-well parameters dozens or even hundreds of times to ensure the optimal full-well performance of the CCD. To achieve this, the general method employed, known as the photon transfer curve method, requires integrating a sphere and other equipment to create a flat-field light source system. However, the resulting system is complex, and hence, it is unsuitable for application in a full-well testing method during the development of an imaging system. In this paper, a novel full-well testing method, a light-emitting diode (LED) point test method, is proposed. Accordingly, CCD full-well testing can be easily realized by developing an LED point light source and common civilian lens. The results reveal that the number of full-well electrons of a spaceborne CCD can reach 817.013ke-, and the error can be less than 0.643%. The results also indicate that the errors resulting from the LED point test method and the traditional method are, respectively, 0.0397% and 1.9% compared with the errors resulting from the photon transfer curve method. In summary, the LED point test method can be used as a general method to rapidly measure the full-well parameters of a CCD under simple conditions, and it can enhance the efficiency of CCD imaging circuit development.
    σ=μ(1)

    View in Article

    μDN-signal=gμE-signal+B(2)

    View in Article

    σDN-noise-shot=gσE-shot-noise(3)

    View in Article

    σtotal2=g2σE-shot-noise2+σread-noise2(4)

    View in Article

    σtotal2=gμDN-signal-B+σread-noise2(5)

    View in Article