• Chinese Journal of Quantum Electronics
  • Vol. 41, Issue 6, 872 (2024)
ZHU Fei1,2,3,*, HOU Zaihong1,3, WANG Gangyu1,2,3, QIN Laian1,3..., JIN Xu1,3 and WU Decheng1,3|Show fewer author(s)
Author Affiliations
  • 1Key Laboratory of Atmospheric Optics, Anhui Institute of Optics and Fine Mechanics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China
  • 2Science Island Branch of Graduate School, University of Science and Technology of China, Hefei 230026, China
  • 3Advanced Laser Technology Laboratory of Anhui Province, Hefei 230037, China
  • show less
    DOI: 10.3969/j.issn.1007-5461.2024.06.004 Cite this Article
    Fei ZHU, Zaihong HOU, Gangyu WANG, Laian QIN, Xu JIN, Decheng WU. Research on calibration method of large‐aperture meter‐scale laser beam quality measuring device[J]. Chinese Journal of Quantum Electronics, 2024, 41(6): 872 Copy Citation Text show less

    Abstract

    With the increasing application of laser, the quality measurement of laser beams with meter-sacle large-aperture is of important research value. To avoid the influence of atmosphere, the wavefront measurement method is gernerally used to directly measure the quality of laser beams with meter-scale large-aperture at the outlet of laser systems. In order to achieve accurate measurement, it is necessary to calibrate the zero point of the meter-scale large-aperture measurement system first. A scanning calibration method for the large-aperture measurement system is proposed in this work using a small aperture calibration light source. The errors of the beam spot centroid shift caused by residual errors of the parallelism of the calibration light source under different scanning mode are analyzed, and the influence of residual errors of the parallelism of the calibration light source on the measurement accuracy in different scanning mode is simulated and analyzed. According to the wavefront restoration results, the unidirectional scanning mode is selected, and it is specified that the residual error of the parallelism of the calibration light source is not greater than 5 μrad when the aperture of scale validation model system is 127 mm, while the residual error of the parallelism of the calibrated light source for the actual measurement system with 1.27 m aperture is not greater than 0.5 μrad.
    Fei ZHU, Zaihong HOU, Gangyu WANG, Laian QIN, Xu JIN, Decheng WU. Research on calibration method of large‐aperture meter‐scale laser beam quality measuring device[J]. Chinese Journal of Quantum Electronics, 2024, 41(6): 872
    Download Citation